• Some health and safety concerns with the Sprint’s Standard Film Developer are may cause skin sensitization. Also could cause mild irritation to skin, eyes, and the respiratory tract, also you don’t want to swallow it. It could absorb through skin and cause life threatening asthma. But don’t worry it will not burn you! In case of fire, use extinguishing media suitable for the material that is burning.

If you were to get chemistry in your eyes you would want to rinse your eyes out with water and it you were contacts you would want to take them out and repeat rinsing your eyes with water for several minutes. But if it doesn’t stop and starts to irritate more seek medical help.

If you were to get chemistry on your skin you would need to wash your skin where to skin and chemical met for several minutes and also you soap. If it persists to irritate the skin seek medical help.

If you were to ingest the chemical you would want to drink plenty of water and try not to vomit. If you do vomit continue to drink plenty more water and seek medical help.

• Some health and safety concerns with using the Sprint’s Quick Silver Print Developer is may cause burns to abraded skin. If you breathe vapors or mist into the body it may cause irritate the mucous membranes of the nose, throat, respiratory tract, and may cause headache, light-headedness, dizziness, and nausea. If you happen to ingest the chemical it could cause gastrointestinal pain, cramps, nausea, vomiting, or central nervous system depression, and may cause kidney or liver damage; can cause life threatening asthma.

If you were to get the chemical in your eye you would need to flush eyes out immediately and remove your contact lenses. Hold your eye lids apart assuring the whole eye is getting water applied to it and do this for 15 minutes. Seek medical attention.

If you were to get the chemical on your skin you would need to wash skin with large amounts of soap and water for 15 minutes. Take off contaminated clothes and shoes. Seek medical attention and before wearing clothes again make sure clothes and shoes are decontaminated.

If you were to ingest the chemical you need to drink 3-4 glasses of water and do not vomit. If you happen to vomit continue drinking more and more water. Seek medical help.

• Some health and safety concerns with using the Sprint’s Block Stop Bath are it may cause mild skin irritation; also may causes eye irritation, and may be harmful if swallowed. Other health issues are may cause respiratory irritation, like in a sore throat, nose and respiratory tract.

If you get the chemical in your eye you need to flush eyes out immediately and remove your contact lenses. Hold your eye lids apart assuring the whole eye is getting water applied to it and do this for 15 minutes. Seek medical attention.

If you get the chemical on your skin you need to wash skin with plenty of soap and water for several minutes. Seek medical attention.

If you were to ingest the chemical you would need to drink 3-4 glasses of water and do not vomit. If you happen to vomit continue drinking more and more water. Seek medical help.

• Some health and safety concerns with using the Sprint’s Record Speed Fix are prolonged and repeat contact to skin may cause irritation, redness, and cracking. Breathing in vapors may irritate the respiratory tract. Contact of product with eyes may irritate and burn eyes. May cause digestive tract irritation and also cause life threatening asthma. 3

If you were to get chemistry in your eyes you would want to rinse your eyes out with water and it you were contacts you would want to take them out and repeat rinsing your eyes with water for several minutes. But if it doesn’t stop and starts to irritate more seek medical help.

If you get the chemical on your skin you need to wash skin with plenty of soap and water for several minutes. Seek medical attention.

If you were to ingest the chemical you would need to drink 3-4 glasses of water and do not vomit. If you happen to vomit continue drinking more and more water. Seek medical help.

• Some health and safety concerns with using the Sprint’s Archive Fix Remover are if Contact of product with eyes may irritate and burn eyes. Can cause kidney damage, and may be toxic to the embryo or cause teratogenic effects also can cause life threatening asthma. Other health issues are may cause respiratory irritation, like in a sore throat, nose and respiratory tract.

If you were to get chemistry in your eyes you would want to rinse your eyes out with water and it you were contacts you would want to take them out and repeat rinsing your eyes with water for several minutes. But if it doesn’t stop and starts to irritate more seek medical help.

If you get the chemical on your skin you need to wash skin with plenty of soap and water for several minutes. Seek medical attention.

If you were to ingest the chemical you would need to drink 3-4 glasses of water and do not vomit. If you happen to vomit continue drinking more and more water. Seek medical help.